Detalye ng Produkto

Bahay / Mga produkto / Yunit ng Air Handing / Uri ng Kisame / Ceiling Ventilation Unit, Dual Fan na may MERV13 Filter, Anti-Short Circuit Design para sa Residential/Commercial Use Air Handling Unit
China Chilled Water Ducted Air Handling Unit AHU
China Chilled Water Ducted Air Handling Unit AHU China Chilled Water Ducted Air Handling Unit AHU
China Chilled Water Ducted Air Handling Unit AHU China Chilled Water Ducted Air Handling Unit AHU
China Chilled Water Ducted Air Handling Unit AHU China Chilled Water Ducted Air Handling Unit AHU
China Chilled Water Ducted Air Handling Unit AHU China Chilled Water Ducted Air Handling Unit AHU
China Chilled Water Ducted Air Handling Unit AHU China Chilled Water Ducted Air Handling Unit AHU
China Chilled Water Ducted Air Handling Unit AHU China Chilled Water Ducted Air Handling Unit AHU

naglo-load

Ceiling Ventilation Unit, Dual Fan na may MERV13 Filter, Anti-Short Circuit Design para sa Residential/Commercial Use Air Handling Unit

Ibahagi sa:
button sa pagbabahagi ng facebook
button sa pagbabahagi ng twitter
pindutan ng pagbabahagi ng linya
buton ng pagbabahagi ng wechat
button sa pagbabahagi ng linkedin
Pindutan ng pagbabahagi ng pinterest
pindutan ng pagbabahagi ng whatsapp
ibahagi ang button na ito sa pagbabahagi
Ang Ceiling fresh air handling unit ay isang energy recovery equipment, na napagtatanto ang panloob at panlabas na pagpapalit ng hangin sa pamamagitan ng mekanikal na supply ng hangin at tambutso, at binabawi ang enerhiya ng tambutso (sensible init o kabuuang init), at angkop para sa mga lugar na may mataas na kalidad ng hangin na kinakailangan tulad ng mga bahay at mga gusali ng opisina.
  • VOLKS

Availability:
Dami:

Mga Tampok ng Ceiling Type Air Handling Unit

Istruktura

  • Heat exchanger: kabuuang init/sensible heat exchange core, na may kahusayan sa pagbawi na 60%-75%.

  • Sistema ng pagsasala: pangunahing+intermediate na filter (opsyonal na H13 na elemento ng filter na may mataas na kahusayan).

  • Fan: double centrifugal fan (air supply+exhaust), mababang ingay na disenyo.


Prinsipyo ng paggawa

  • Ang panlabas na sariwang hangin at panloob na tambutso ay nagpapalitan ng enerhiya sa pamamagitan ng heat exchange core, at ang purified fresh air ay ipinadala sa silid, at ang maruming hangin ay pinalabas, kaya binabawasan ang pagkarga ng air conditioning.

Mga Parameter ng Produkto

Modelo Dami ng hangin Bilang ng
mga row ng coil
Sariwang air condition Ibalik ang air condition ng inlet at
outlet
ng tubo
Diametro
Diameter ng condensate
pipe
ng paglamig
Kapasidad
ng pag-init
Kapasidad
tubig
Paglabas ng
ng paglamig
   Kapasidad
ng pag-init
   Kapasidad
tubig
Paglabas ng
VFC(S) m³/h R kW kW L/S kW kW L/S DN DN
015 1500 4 18.6 19.7 0.9 9.3 16.7 0.5 32 32
6 23.4 22.5 1.2 11.7 18.9 0.6
8 25.5 25.2 1.3 12.8 23.7 0.7
020 2000 4 24.8 26.2 1.2 12.4 22.2 0.6 32 32
6 31.2 30.0 1.5 15.6 25.2 0.8
8 34.0 33.6 1.7 17.0 31.6 0.9
025 2500 4 31.0 32.8 1.5 15.5 27.8 0.8 32 32
6 39.0 37.5 1.9 19.5 31.5 1.0
8 42.5 42.0 2.1 21.3 39.5 1.1
030 3000 4 37.2 39.3 1.8 18.6 33.3 0.9 32 32
6 46.8 45.0 2.3 23.4 37.8 1.2
8 51.0 50.4 2.5 25.5 47.4 1.3
040 4000 4 49.6 52.4 2.4 24.8 44.4 1.2 40 32
6 62.4 60.0 3.0 31.2 50.4 1.5
8 68.0 67.2 3.3 34.0 63.2 1.7
050 5000 4 62.0 65.5 3.0 31.0 55.5 1.5 40 32
6 78.0 75.0 3.8 39.0 63.0 1.9
8 85.0 84.0 4.1 42.5 79.0 2.1
060 6000 4 74.4 78.6 3.6 37.2 66.6 1.8 40 32
6 93.6 90.0 4.5 46.8 75.6 2.3
8 102.0 100.8 4.9 51.0 94.8 2.5
070 7000 4 86.8 91.7 4.2 43.4 77.7 2.1 50 32
6 109.2 105.0 5.3 54.6 88.2 2.7
8 119.0 117.6 5.7 59.5 110.6 2.9
080 8000 4 99.2 104.8 4.8 49.6 88.8 2.4 50 32
6 124.8 120.0 6.0 62.4 100.8 3.0
8 136.0 134.4 6.5 68.0 126.4 3.3
100 10000 4 124.0 131.0 6.0 62.0 111.0 3.0 65 32
6 156.0 150.0 7.5 78.0 126.0 3.8
8 170.0 168.0 8.2 85.0 158.0 4.1
120 12000 4 148.8 157.2 7.2 74.4 133.2 3.6 65 32
6 187.2 180.0 9.0 93.6 151.2 4.5
8 204.0 201.6 9.8 102.0 189.6 4.9
135 13500 4 167.4 176.9 8.0 83.7 149.9 4.0 65 32
6 210.6 202.5 10.1 105.3 170.1 5.1
8 229.5 226.8 11.0 114.8 213.3 5.5
150 15000 4 186.0 196.5 8.9 93.0 166.5 4.5 65 32
6 234.0 225.0 11.2 117.0 189.0 5.6
8 255.0 252.0 12.2 127.5 237.0 6.1


Kalamangan ng produkto at Application

Kalamangan ng produkto

  • Pagtitipid ng enerhiya at proteksyon sa kapaligiran: binabawasan ng teknolohiya ng pagbawi ng init ang pagkonsumo ng enerhiya ng higit sa 30%.

  • Two-way na bentilasyon: pantay na pagpapalit ng hangin upang mapanatili ang panloob na positibo o negatibong presyon.

  • Tahimik na disenyo: mababang operasyon ng ingay (36-49dB).


Mga sitwasyon ng aplikasyon

  • Mga bahay at apartment: pagbutihin ang panloob na kalidad ng hangin at maiwasan ang polusyon sa dekorasyon.

  • Opisina at negosyo: conference room, hotel room, hospital operating room.

  • Pang-industriya na malinis na silid: elektronikong pabrika, pagawaan ng parmasyutiko at iba pang mga lugar na nangangailangan ng patuloy na temperatura at halumigmig.

Mga Tagubilin sa Pagpapanatili ng Kagamitan

Pang-araw-araw na pagpapanatili

  • Pagpapalit ng filter: ang pangunahing filter ay nililinis tuwing 2 buwan, at ang intermediate na filter /H13 na filter ay pinapalitan tuwing 6 na buwan (depende sa antas ng polusyon).

  • Inspeksyon ng air inlet at outlet: alisin ang sagabal sa air outlet para matiyak na walang short circuit sa air supply at exhaust flow.


Regular na pagpapanatili (quarterly)

    Paglilinis ng heat exchange core:

  • Sensible core: nililinis ng vacuum cleaner ang alikabok sa ibabaw.

  • All-hot core: ibabad sa neutral na detergent at tuyo. Ipinagbabawal ang pagkakalantad o high-pressure na pag-flush ng tubig.

  • Pag-inspeksyon ng fan: subukan ang pagkakapare-pareho ng bilis ng blower/exhauster, at subaybayan ang abnormal na tunog (kailangang palitan ang bearing wear sa oras).

  • Pag-calibrate ng sensor: suriin ang katumpakan ng temperatura at halumigmig at data ng sensor ng CO.


Pana-panahong pagpapanatili

  • Pag-iwas sa frost sa taglamig: i-on ang preheating function o bawasan ang dami ng hangin ng tambutso upang maiwasan ang pagyeyelo ng heat exchange core.

  • Moistureproof sa tag-ulan: suriin ang halumigmig sa loob ng makina at simulan ang dehumidification mode kung kinakailangan.

Mga pag-iingat sa kaligtasan

  • I-off ang power supply kapag pinapalitan ang screen ng filter upang maiwasan ang pagsisimula ng fan.

  • Ang init exchange core ay dapat na selyadong at mapangalagaan pagkatapos disassembly upang maiwasan ang pagpapapangit dahil sa kahalumigmigan.

FAQ

Q: Ano ang dahilan ng hindi sapat na dami ng sariwang hangin? Paano ito lutasin?

A: ang filter na screen ay na-block o ang fan ay nababaligtad. Kailangang linisin/palitan ang screen ng filter, o ayusin ang pagkakasunud-sunod ng power phase.


Q: Ano ang dahilan ng pagbaba ng kahusayan sa pagpapalitan ng init? Paano ito lutasin?

A: Ang dami ng exchange core ay kulay abo o nagyelo. Kinakailangan na regular na linisin ang core at painitin ang sariwang hangin sa taglamig.

Mga Mabilisang Link

Kategorya ng Produkto

Tungkol sa VOLKS

Mga mapagkukunan

Makipag-ugnayan sa Amin

 Email: james@sdvolksgroup.com
 Tel: +86- 13310606210
 WhatsApp: +86 13310606210
Address: East Tianqu Road, Zhongao Street, Economic and Technological Development Zone, Dezhou city, Shandong province, China. 253000
Copyright © 2024 Shandong VOLKS Air Conditioning Group Co., Ltd. Lahat ng Karapatan ay Nakalaan. Sitemap. Patakaran sa Privacy.